By buying this product you can collect up to 20 loyalty points. Your cart will total 20 loyalty points that can be converted into a voucher of 4,00 €.
Phoenix VE.Direct 12/24/48V - 800VA
Victron Phoenix Converter VE.Direct 12/24/48 / 800VA.
Developed for professional use, the range of Phoenix converters is perfectly adapted to the most diverse applications.
Recipient :
* Required fields
or Cancel
New product
Victron Phoenix Converter VE.Direct 12/24/48 / 800VA.
Developed for professional use, the range of Phoenix converters is perfectly adapted to the most diverse applications.
Warning: Last items in stock!
Availability date: 0000-00-00
The VE.Direct port can be connected to:
• A computer (VE.Direct-USB interface cable required).
• Apple and Android smartphones, tablets, macbooks and other devices (a Bluetooth Smart dongle communicating with VE.Direct is required).
• Reset levels and alarm triggering in case of low battery voltage
• Restart and shutdown levels in case of low battery voltage
• Dynamic shutdown: cutoff level according to load
• Output voltage 210 - 245 V
• 50 Hz or 60 Hz output frequency
• ECO mode detection level and ECO mode on / off
• Input and output voltage,% load and alarms
The complete bridge topology with a toroidal transformer has proven its reliability for years. The inverters are protected against short circuits and overheating, whether overload or high ambient temperature.
Required to start loads such as power converters for LED bulbs, halogen bulbs or power tools.
In ECO mode, the inverter will switch to pause if the load falls below a predetermined value (minimum load: 15 W). Once paused, the converter will turn on for a short period of time (adjustable, default: every 2.5 seconds). If the load exceeds a preconfigured level, the converter will remain on.
A red LED and a green LED indicate the operation of the converter and the status of the different protections
A remote start / stop switch can be connected to a two-pole connector or between the positive pole of the battery and the left contact of the two-pole connector.
For our low power converters, we recommend the use of our Filax automatic transfer switch. The Filax has a very fast transfer time (less than 20 milliseconds) so that computers and other electronic equipment can continue to operate without interruption.
No specific tools are required for installation.
Technical characteristic:
Phoenix converter | 12V / 800 24V / 800 48V / 800 |
Continuous power at 25 ° C (1) | 800 VA |
Continuous power at 25 ° C / 40 ° C | 650/560 W |
Peak power | 1500 W |
Frequency / AC output voltage (adjustable) | 230 VAC or 120 VAC +/- 3% 50 Hz or 60 Hz +/- 0.1% |
Supply voltage range | 9.2 - 17 V 18.4 - 34.0 V 36.8 - 62.0 V |
DC low current stop (adjustable) | 9.3 V 18.6 V 37.2 V |
Dynamic (depending on the load) Low DC current stop (fully adjustable) | Dynamic break |
Alarm and low DC restart (adjustable) | 10.9V 21.8V 43.6V |
Battery charge detection (adjustable) | 14.0V 28.0V 56.0V |
Maximum efficiency | 90% 90% 91% |
Vacuum consumption | 6.5 W 7 W 9.5 W |
Default vacuum consumption in ECO mode (default retry interval: 2.5 s, adjustable) | 1 1.5 3.0 |
Power setting start and stop in ECO mode | Adjustable |
Protection | a) short circuit output b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) DC ripple too high |
Operating temperature range | -40 to + 65 ° C (fan cooling) (1.25% reduction per ° C above 25 ° C) |
Humidity (without condensation) | max 95% |
HOUSING | |
Material and color | Steel frame and plastic cover (Blue RAL 5012) |
Battery connection | Screw terminals |
Maximum cable section | 25/10/10 mm² / AWG4 / 8/8 |
Standard AC sockets | 230 V: Schuko (CEE 7/4), IEC-320 (plug included) UK (BS 1363), AU / NZ (AS / NZS 3112) 120 V: Nema 5-15R |
Degree of protection | IP 21 |
Weight | 5.5 kg |
Dimensions (HxWxD in mm) | 105 x 216 x 305 (12V model: 105 x 230 x 325) |
ACCESSORIES | |
Remote on / off switch | Yes |
Automatic transfer switch | Filax |
STANDARDS | |
security | EN-IEC 60335-1 / EN-IEC 62109-1 |
EMC | EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3 |
Automobile Directive | ECE R10-4 |
1) Nonlinear load, crest factor 3: 1 |
No customer reviews for the moment.